Time-domain reflectometry

Time-domain reflectometry or TDR is a measurement technique used to determine the characteristics of electrical lines by observing reflected waveforms.[1] Time-domain transmissometry (TDT) is an analogous technique that measures the transmitted (rather than reflected) impulse. Together, they provide a powerful means of analysing electrical or optical transmission media such as coaxial cables and optical fibers.

Variations of TDR exist. For example, spread-spectrum time-domain reflectometry (SSTDR) is used to detect intermittent faults in complex and high-noise systems such as aircraft wiring.[2] Coherent optical time domain reflectometry (COTDR) is another variant, used in optical systems, in which the returned signal is mixed with a local oscillator and then filtered to reduce noise.[3]

The amplitude of the reflected signal can be determined from the impedance of the discontinuity. The distance to the reflecting impedance can also be determined from the time that a pulse takes to return. The limitation of this method is the minimum system rise time. The total rise time consists of the combined rise time of the driving pulse and that of the oscilloscope that monitors the reflections.

Contents

Method

The TDR analysis begins with the propagation of a step or impulse of energy into a system and the subsequent observation of the energy reflected by the system. By analyzing the magnitude, duration and shape of the reflected waveform, the nature of the impedance variation in the transmission system can be determined.

Resistive load

If a pure resistive load is placed on the output of the reflectometer and a step signal is applied, a step signal is observed on the CRT, and its height is a function of the resistance. The magnitude of the step caused by the resistive load may be expressed as a fraction of the input signal as given by:

\rho = \frac{R_L - Z_0}{R_L %2B Z_0}

where Z_0 is the characteristic impedance of the transmission line.

Reactive load

For reactive loads, the observed waveform depends upon the time constant formed by the load and the characteristic impedance of the line.

See also

References

  1. ^ Furse, Cynthia, Lo, Chet. "Reflectometry for Locating Wiring Faults". IEEE Transactions on Electromagnetic Compatibility. February, 2005
  2. ^ Smth,Paul, Furse, Cynthia and Gunther, Jacob. "Analysis of Spread Spectrum Time Domain Reflectometry for Wire Fault Location." IEEE Sensors Journal. December, 2005.
  3. ^ José Chesnoy (ed.), Undersea Fiber Communication Systems, Elsevier Science, 2002, ISBN 0-12-171408-X, p.171 (COTDR)